When winter’s chill sets in, a power outage can leave you shivering in the dark. This is when a generator can become your best friend, supplying the power needed to keep your heating system running. However, if you find that your furnace won’t run when connected to a generator, it can be a source of frustration and discomfort.
Why Won’t My Generator Run My Furnace? Your generator may not run your furnace due to compatibility issues, bonding problems between neutral and ground, or inadequate generator wattage.

See Also: Where Is the T1 Fuse on a Generac Generator?
Why Won’t My Generator Run My Furnace? – Guide
In this comprehensive guide, we will explore the top reasons why your furnace may refuse to cooperate with your generator and offer practical solutions to address these issues.
Whether you are dealing with compatibility problems, electrical issues, or power output concerns, we’ve got you covered.
1. The Furnace Can’t Run on Inverted Power
Understanding Compatibility
One of the most common reasons your furnace may not run on a generator is due to compatibility issues. Generators often use inverted power to deliver electricity efficiently to various devices. However, not all furnaces are compatible with inverted power.
Some rely on standard power, and when the generator uses an inverter to convert power to AC, your furnace may refuse to start. This incompatibility can be a significant barrier to keeping your home warm during a power outage.
How to Fix
The solution to this issue depends on the type of generator you have. To determine if your generator uses inverted power, consult the manufacturer’s manual or website.
If you find that the generator uses inverted power, compare it with your furnace’s power requirements.
In some cases, you may have the option to switch off the inverter via an inverter switch on your generator. If this switch is available, try turning it off and then attempt to start your furnace.
If the generator lacks this option, you may need to consider acquiring a different generator that is compatible with your furnace’s power requirements.
It’s also a good idea to test with another generator that does not use inverted power. Borrow one from a friend or rent one to check if this resolves the issue.
2. No Bonding Between Neutral and Ground
Electrical Bonding Issues
Another possible reason for your furnace not running on a generator is the absence of bonding between the neutral and ground lines. This is a surprisingly common issue, particularly with new generators, including portable models.
When the neutral and ground lines are not bonded, it can impede the furnace from receiving the power it needs to operate, as the bonded connection is a safety measure when starting the furnace.
How to Fix
Fixing this problem may not be as straightforward as you’d hope. It involves working with the generator’s electrical system. If you are experienced in handling electrical systems and wiring, you can attempt this fix yourself. However, if you lack the expertise, it’s safer to hire an electrician to perform the task.
Here’s a general outline of the steps you need to follow:
- Turn off the generator.
- Open the generator’s main panel to access its internal wiring.
- Identify the neutral and ground wires.
- Bond the neutral and ground wires. The precise method may vary depending on the generator’s model.
- Replace the cover on the generator.
- Reconnect the generator to the furnace and power it on. Check if the problem has been resolved. If not, you may need to investigate further to identify any other issues within the system.
3. Incompatible Generator Wattage
Ensuring Wattage Compatibility
Wattage plays a crucial role in determining whether your generator can effectively power your furnace. Before committing to a specific generator-furnace combination, it’s essential to verify that the two appliances are compatible in terms of wattage.
How to Fix
To address this issue, you need to evaluate the wattage output of your generator and compare it to the wattage requirements indicated on your furnace’s label. If the numbers do not match, it’s likely the source of the problem.
In an ideal situation, your generator should have a higher wattage rating than what your furnace needs. However, there are instances where portable generators may offer just enough power for essential devices, resulting in a low wattage rating.
Some generators come with an “Eco” mode that provides a lower wattage output to conserve fuel. If your generator features this mode, try turning it off and see if it provides adequate power for your furnace to start. If the problem persists, you may need to consider replacing either the main furnace module or the generator.
If your generator is relatively new, there may be an opportunity to exchange it for a larger model, provided you are willing to pay any additional costs.
4. Fuel Tank Is Low
Gasoline and Propane Concerns
While the previous sections primarily addressed compatibility and electrical issues, your generator’s ability to run your furnace can also be influenced by fuel-related problems.
For generators that run on gasoline, it’s crucial to maintain an adequate fuel supply. Check the fuel levels in the tank and ensure they are not running low. If the fuel levels are insufficient, simply add more fuel.
For propane-fueled generators, confirm the fuel level and ensure that all valves and tubing connecting the propane tank to the generator are open. A lack of fuel can prevent the generator from starting.
Preventing Fuel Staleness
One important consideration when using gasoline is the age of the fuel. “Stale” gasoline, which is gas that is more than two months old, can damage the generator’s engine.
If you suspect stale gasoline, drain it from the fuel tank and the carburetor. Then, refill the tank with fresh gasoline to avoid engine damage and ensure reliable generator operation.
5. Low Oil Levels in the Engine
The Importance of Proper Oil Levels
Oil is a critical component for your generator’s engine. While most generators have sensors to alert you when oil levels are low, it’s still essential to manually check the oil levels using a dipstick. Low oil levels can lead to engine damage and potentially expensive breakdowns.
How to Fix
If you discover that your generator’s oil levels are low, refill it with the recommended oil type as indicated in the manufacturer’s instructions. This is also an excellent time to replace the oil filter to maintain your generator’s optimal performance and prevent unexpected issues.
6. Dead Battery
Addressing Battery Problems
Just like your car, a dead or faulty battery can prevent your generator from starting. If you’ve ruled out other causes and suspect the battery, try charging it through a 12-volt DC outlet or jump-start it using your car’s battery.
If these attempts do not resolve the issue, the battery is likely not the problem, and you should explore other possibilities.
7. Cables Are Plugged into the Generator
Eliminating External Factors
Before attempting to start your generator, check to ensure that no cables or appliances are plugged into it. Even if these cords are not connected to any devices, unplug them to rule out any external factors that may be preventing your generator from starting.
8. Adjust the Choke Control
Managing the Choke
The choke on your generator regulates the air levels within the carburetor during engine startup. If your generator’s engine struggles to turn over, it may be due to incorrect choke settings.
In cold conditions, the choke should be closed completely. As the engine warms up, you can gradually adjust the choke to open fully. However, if the engine is already warm, the choke should be halfway open to facilitate a restart.
9. Clogged Air Filter
Air Filter Inspection
If adjusting the choke helps but does not completely resolve the problem, inspect the air filter. A clogged air filter can obstruct the flow of air necessary for combustion. You can easily examine the air filter, and if it appears dirty, replace it and reset the choke to a closed position.
10. Dirty Spark Plug
Spark Plug Examination
If you have gone through the previous steps and the engine still refuses to turn over, a dirty or malfunctioning spark plug may be the culprit. Remove the spark plug and replace it if you observe:
- The spark plug is covered with dirt or debris that cannot be cleaned.
- Signs of broken electrodes or cracks.
If you can remove the debris, clean the spark plug meticulously and adjust the electrode gap as per the generator owner’s manual. To test the spark plug, hold it against the engine’s crankcase and pull the generator’s recoil starter. If the spark plug is functioning correctly, you will see blue sparks. Reinstall the spark plug and attempt to start the generator again.
11. Clogged Carburetor
Addressing Fuel Flow
By now, you may have already drained the carburetor when dealing with stale gasoline, but if not, it’s essential to check it for clogs. Old gasoline can create blockages in the carburetor, preventing new fuel from reaching the combustion chamber.
To clean the carburetor, begin by closing the fuel valve. Remove the bowl located at the bottom of the carburetor and use a brush or towels to remove any debris. If there are clogs in the brass jet nozzle, use a needle or straight pin to clear them. After cleaning, turn the fuel valve back on and try restarting the generator.
12. Clogged Fuel Valve
Ensuring Fuel Flow
If your carburetor was clogged, there is a possibility that the fuel valve is also obstructed. Ensure that both the fuel and vacuum relief valves above the generator’s gas tank are open.
If your generator still does not start, unplug the fuel hose and check if gasoline flows through the fuel line. Have a container ready to catch the fuel during this test. Additionally, inspect the filter between the fuel valve and carburetor for any clogs.
13. Oil Level Sensor Malfunctioning
Oil Sensor Reliability
The low oil sensor in your generator is responsible for indicating when engine oil levels are too low. If this sensor malfunctions, it can lead to erroneous readings and prevent the generator from starting. An uneven surface can also affect oil levels, leading to misreadings by the sensor.
Position your generator on an even surface. If the oil sensor continues to indicate low levels, disconnect the sensor and attempt to run the engine. If the engine starts, the sensor is likely at fault. Reconnecting it may reboot it, but if not, you should consider replacing the sensor.
Generator Repair
After exploring these common generator issues and attempting the suggested fixes, if your generator still refuses to start, or if you lack confidence in your troubleshooting skills, it’s advisable to seek professional generator repair services.
Professional technicians have the knowledge and experience to diagnose and repair your generator efficiently. They can also guide you in selecting a new generator if your current one is beyond repair.
Conclusion
In conclusion, when your furnace won’t run on a generator, it can be due to various reasons, such as compatibility issues, electrical problems, or insufficient power output.
By understanding these potential causes and following the appropriate troubleshooting steps, you can increase the likelihood of getting your generator and furnace back up and running during those cold winter power outages.
Remember that in case of any doubts or persistent issues, professional assistance is readily available to ensure your home remains warm and comfortable even in the darkest of times.
Now, you should be well-equipped to troubleshoot and resolve generator-furnace compatibility issues effectively and ensure that you stay warm during power outages in the winter months.
Read Also: What Size Generator for Dj Equipment?